The Floating Floor Solution for Soundproofing a Concrete Floor.

 
  High soundproofing performance and surpasses building regulations while losing minimal room height. This is the Ideal Solution to Soundproofing a Concrete Floor when there is no access to the ceiling below, for higher performance with ceiling access see the Floating Floor Solution with Decoupled Ceiling Below.  
  Soundproofing a concrete floor from above only


Floating Floor Solution (15mm Above)

Application: Building Regulations New Build, Change of Use, Remedial and Refurbishment.
Simple slim solution offering a high performance and absolute minimal loss of living space, where there is only access to the floor above and no access to the ceiling below e.g. in apartment dwellings.

Construction: (Solid / Concrete Floor):
- sacrificial layer or FINISHED surface
- 15mm Phonewell® Sound Insulation
- solid concrete floor

 
 

Materials List (available from our stockists)
- Phonewell® Acoustic Insulation on Floor (1200mm x 800mm x 15mm)
- Phonewell® Eco-Tape

Instructions: (have you considered Flanking Noise?)
Floor
1.
Treat new concrete floors with a damp proof membrane.
2. Ensure the floor is clean, dry and sufficiently level. If required any unevenness can be levelled out with sand, but Phonewell® does have minor correction capabilities.
3. Begin in one corner and lay the Phonewell® boards on the concrete floor, butted tightly up to the perimeter walls.  Do not screw or nail the boards down.
4. Butt each Phonewell® board up tightly to each other, leaving no gaps.  Lay the boards in a brickwork formation.  See Cutting Phonewell®.
5. Install the finished floor surface as per Fitting Floor Finishes over Phonewell®.
6. Fit skirting boards ensuring no contact with the floor – leave a 2mm gap.
7. Consider treating any identified flanking walls with Phonewell®.

 
 
Sound Insulation the Natural Way
The Highest Airborne Sound Reduction Impact Sound Reduction Outstanding at Low Frequencies; Correction Factor Sound Insulation at only 15mm thick